Fan for turbo boilers 960258010
The fan with article number 960258010 is designed for use in gas boilers with a sealed combustion chamber. It is installed in boilers of the Sime brand, including models Format Zip 25 BF and Metropolis Dgt 25 BF, and is also compatible with other brands such as Termet, Immergas, Alpha, and Biasi. This fan can also be used as a turbo attachment for floor-standing boilers.
Functional features:
- Designed for boilers with a sealed combustion chamber.
- Fan power: 30 W.
- Effectively removes flue gases through a double coaxial pipe.
- The fan housing is made of stamped sheet steel, ensuring durability and corrosion resistance.
- Equipped with a bearing integrated on the rotating shaft to extend its service life.
Operating principle:
The fan ensures the removal of flue gases from the combustion chamber through the outer wall or roof using a special coaxial pipe. This makes it an ideal solution for boilers with a sealed combustion chamber, enhancing their efficiency and operational safety.
Compatibility:
To find the required model, use the keyboard shortcut Ctrl+F.
| Brand | Models |
| Sime | Format Zip 25 BF, Metropolis Dgt 25 BF |
| Termet | Compatible with models of this brand |
| Immergas | Compatible with models of this brand |
| Alpha | Compatible with models of this brand |
| Biasi | Compatible with models of this brand |
Advantages:
- High performance and energy efficiency with a power of 30 W.
- Versatility: compatible with a wide range of boilers from different brands.
- Ease of installation and operation.
How to choose the right part:
To avoid mistakes when selecting a fan, pay attention to the following points:
- Ensure that the part number matches your original fan.
- Check compatibility with your boiler using the compatibility table above.
- Make sure the fan power matches the specifications of your device.
Possible causes of failure:
- Bearing wear: can lead to noise and reduced performance.
- Corrosion of the housing: if the fan is installed in high humidity conditions.
- Clogging: accumulation of dirt and dust can block the fan's operation.
Methods to prevent damage:
- Regularly clean the fan from dust and debris.
- Ensure proper ventilation around the boiler to prevent corrosion.
- Monitor the condition of the bearings and replace them if necessary.
Replacement recommendations:
- Disconnect the boiler from the power supply and gas for safety.
- Remove the boiler cover to access the fan.
- Disconnect the electrical wires from the old fan.
- Unscrew the fasteners and carefully remove the old fan.
- Install the new fan by following the reverse order.
- Reconnect the electrical wires and ensure a secure connection.
- Close the boiler cover and reconnect it to the power supply.
Difficulty of replacement:
Replacing the fan 960258010 has a medium level of difficulty. It can be done independently if you have basic skills in electronics and plumbing. However, if you are unsure of your abilities, it is recommended to consult a professional for the replacement.
The fan 960258010 is an essential component of the heating system, ensuring efficient operation of boilers with a sealed combustion chamber. Quality materials and reliable construction guarantee long-term operation and safety.