Quantity
|
Out of stock
|
||
|
|
|||
|
|
|||
Universal outdoor unit air conditioner motor 20W (YPY-20-6_L)
The universal outdoor unit air conditioner motor is designed to ensure the operation of air conditioners, providing efficient cooling and maintaining the desired temperature indoors. With a power of 20W and an operating voltage of 220-240V, this motor is ideal for replacing old or faulty units, ensuring reliable operation of your climate systems.
Technical specifications
| Voltage and frequency | 220-240V ~ 50Hz |
| Power | 20W (0.2A) |
| Rotation direction | Clockwise |
| Shaft diameter | 8 mm |
| Total shaft length (± 1 mm) | 57 mm |
| Impeller fitting | 1 flat, 7 mm |
| Flat length (± 1 mm) | 21 mm |
| Thread diameter | 6 mm |
| Thread length (± 1 mm) | 11 mm |
| Body diameter (± 1 mm) | 96 mm |
| Body height (± 1 mm) | 75 mm |
| Connection | 3 terminals + 1 ground |
| Features | IP 44, Class B |
| Mounting | 4 holes d=5.2 mm, l=90 mm |
| Marking | YPY-20-6 |
| Manufacturer | China |
How to choose the right product
When selecting a universal motor for an outdoor air conditioner unit, pay attention to the following parameters:
- Voltage and frequency: Ensure they match the requirements of your device.
- Power: Choose a motor with similar specifications to avoid overheating and damage.
- Dimensions: Check the shaft diameter and length, as well as the body dimensions for proper installation.
- Rotation direction: Ensure the motor rotates in the same direction as the original.
Possible causes of failure and prevention methods
The motor may fail due to the following reasons:
- Overheating: Often caused by improper installation or blockage of ventilation openings.
- Bearing wear: Regular lubrication and cleaning can help extend the lifespan.
- Electrical issues: Damaged wires or incorrect connections can lead to failure.
To prevent wear, it is recommended to regularly check the condition of the motor and clean it from dust and dirt.
Difficulty of part replacement
Replacing the universal outdoor unit air conditioner motor is of moderate difficulty and can be done independently with basic tool skills. It is recommended to follow this step-by-step guide:
- Disconnect the power to the air conditioner.
- Remove the cover of the outdoor unit.
- Disconnect the electrical connections from the old motor.
- Remove the fasteners and extract the old motor.
- Install the new motor, secure it, and connect the electrical connections.
- Check the operation of the air conditioner and reassemble the casing.
If you lack experience or confidence in your abilities, it is advisable to consult a professional technician for the replacement.