Thermostat for Thermex boiler 16A 250V L=570mm, 20-75°C WY75-652-11R
Description:
The WY75-652-11R thermostat is designed to regulate and maintain the temperature in boilers. It provides precise temperature control in the range of 20 to 75°C, helping to prevent overheating of the water. This thermostat is suitable for use with various boiler models and is a reliable component for maintaining optimal thermal conditions.
Specifications:
| Voltage: | 250V |
| Current: | 16A |
| Temperature range: | 20-75°C |
| Capillary length: | 570 mm |
| Manufacturer: | WILLER |
| Brand: | WILLER, Ariston, TESY, Thermex |
| Part type: | Thermostat, temperature regulator |
Compatible models:
- WILLER EH100R Spring
- WILLER EH20R Edge+
- WILLER EH40R Spring
- WILLER EH50R Spring
- WILLER EH60R Spring
- WILLER EH80R Spring
- WILLER EV100DR Fine DHE
- WILLER EV100DR Grand
- WILLER EV100DR Optima
- WILLER EV30DR Optima
- WILLER EV50DR Fine DHE
- WILLER EV50DR Grand
- WILLER EV50DR Optima
- WILLER EV80DR Fine DHE
- WILLER EV80DR Grand
- WILLER EV80DR Optima
- WILLER EVH100R Spring
- WILLER EVH100R Strong
- WILLER EVH30R Spring
- WILLER EVH50R Spring
- WILLER EVH50R Strong
- WILLER EVH80R Spring
- WILLER IV50R Ultra
- WILLER IVB50DR elegance
- WILLER IVB50DR metal elegance
- WILLER IVB80DR elegance
- WILLER IVB80DR metal elegance
- WILLER IVH50R Flat NHE
- WILLER IVH50R Uni NHE
- WILLER IVH80R Flat NHE
- WILLER IVH80R Uni NHE
- WILLER PA10R Optima Mini
- WILLER PA15R Optima Mini
- WILLER PU10R Optima Mini
- WILLER PU15R Optima Mini
- WILLER PU25R Optima Mini
- WILLER PU6R Optima Mini
- Ariston NTS FLAT 100 V (RE) 3605507C
- Ariston NTS FLAT 100 V (RE) 3605507
- Ariston NTS FLAT 100 V (RE) 3605507S
- Ariston NTS FLAT 100 V (RE) 3605507R
- Ariston NTS FLAT 100 V (RE) 3605507F
- Ariston NTS FLAT 30 V (RE) 3605504
- Ariston NTS FLAT 30 V (RE) 3605504S
- Ariston NTS FLAT 30 V (RE) 3605504R
- Ariston NTS FLAT 30 V (RE) 3605504F
- Ariston NTS FLAT 30 V (RE) 3605504C
- Ariston NTS FLAT 50 V (RE) 3605505
- Ariston NTS FLAT 50 V (RE) 3605505S
- Ariston NTS FLAT 50 V (RE) 3605505R
- Ariston NTS FLAT 50 V (RE) 3605505F
- Ariston NTS FLAT 50 V (RE) 3605505C
- Ariston NTS FLAT 80 V (RE) 3605506S
- Ariston NTS FLAT 80 V (RE) 3605506R
- Ariston NTS FLAT 80 V (RE) 3605506F
- Ariston NTS FLAT 80 V (RE) 3605506C
- Ariston NTS FLAT 80 V (RE) 3605506
- TESY GCU 0615 M01 RC
- Thermex ERS 150 V
How to choose the right part:
When selecting a thermostat, consider the following:
- Voltage and current: Ensure that the thermostat's specifications match your boiler's requirements.
- Temperature range: Check that the thermostat's temperature range meets your needs.
- Capillary length: Make sure the capillary length fits the installation requirements of your device.
- Compatibility: Review the list of compatible models to avoid mistakes when purchasing.
Possible causes of failure:
The thermostat may fail for the following reasons:
- Overheating due to a faulty heating element.
- Wear and tear from prolonged use.
- Incorrect installation or connections.
Prevention recommendations:
To avoid thermostat failures, it is recommended to:
- Regularly check the condition of the heater and control system.
- Avoid overheating the water in the boiler.
- Perform timely maintenance and cleaning of the boiler.
Replacing the thermostat: steps
- Disconnect the boiler from the power supply.
- Drain the water from the boiler to prevent leaks.
- Remove the boiler cover to access the thermostat.
- Disconnect the old thermostat, noting the order of the wire connections.
- Install the new thermostat in place of the old one, following the connection order.
- Secure the boiler cover and reconnect it to the power supply.
- Fill the boiler with water and check the operation of the new thermostat.
Difficulty of replacement:
Replacing the thermostat is of medium difficulty. It is recommended to seek assistance from a professional if you are unsure of your abilities or lack experience with such tasks.