Snail for pump under "Zhiguli" seal BCN
Description: The snail for the pump is designed for use in pumps compatible with the BCN model. Made from durable aluminum alloy, this part ensures reliability and longevity. It is ideal for vertical pumps and under the "Zhiguli" seal, the snail is easy to install and replace.
Technical specifications
| Parameter | Value |
|---|---|
| Compatibility | BCN |
| Purpose | For pumps |
| Type | Spare parts |
| Overall diameter | 205 mm |
| Overall height | 138 mm |
| Threaded outlet hole | 5/4" |
| Mounting to electrical part | 3 holes |
| Cover-shield mounting | 6 holes with M6 threads |
| Material | Aluminum alloy |
| Quantity, pcs | 1 |
| Country of manufacture | Ukraine |
| Additional characteristics | For vertical pump. Under "Zhiguli" seal |
Compatibility with models
- BCN 1.1
- BCN 1.2
- BCN 1.6
How to choose the right spare part?
When selecting a snail for the pump, pay attention to the following points:
- Dimensions: Ensure that the diameter and height of the part meet your requirements.
- Compatibility: Check that the model of the snail fits your pump (in this case, BCN).
- Material: Prefer parts made of aluminum alloy for greater strength and corrosion resistance.
Causes of failure and prevention
The snail may fail for several reasons:
- Wear and damage to the seal.
- Incorrect installation or mounting, leading to vibration.
- Overheating due to insufficient cooling.
To avoid failures, follow these recommendations:
- Regularly check and replace seals.
- Ensure proper installation and mounting.
- Monitor the operating temperature of the pump.
Recommendations for replacing the snail
- Disconnect the pump from the power supply.
- Drain water from the pumping system.
- Remove the screws holding the snail.
- Carefully extract the old snail.
- Install the new snail, ensuring correct orientation.
- Secure the snail with screws.
- Reconnect the pump to the power supply and check its operation.
Difficulty of replacement
Replacing the snail is of medium difficulty. It can be performed by one person, but it is recommended to work in pairs for convenience and safety. By following the outlined steps, you can easily replace the snail and extend the lifespan of your pump.