Quantity
|
Out of stock
|
||
|
|
|||
|
|
|||
Fan gasket for Nova Florida gas boiler (6ORVENCA00)
The fan gasket for Nova Florida gas boilers is designed to ensure a tight seal between the fan and the boiler casing. This component plays a crucial role in preventing gas leaks and maintaining the efficient operation of heating equipment. The gasket has an inner diameter of 106 mm, an outer diameter of 110 mm, and a thickness of 2 mm, making it compatible with a range of boiler models.
Technical specifications
| Specification | Value |
|---|---|
| Inner diameter | 106 mm |
| Outer diameter | 110 mm |
| Thickness | 2 mm |
Compatibility with models
The gasket is suitable for the following boiler models:
- Fondital
- Flores Dual Line CTFS 24 AF
- Nias Dual BTFS 24
- Nias Dual BTFS 28
- Nias Dual BTFS 32
- Nias Dual Line BTFS 24
- Nias Dual Line BTFS 28
- Nias Dual Line BTFS 32
- Tahiti Dual CTFS 24
- Tahiti Dual CTFS 28
- Tahiti Dual Line CTFS 24
- Tahiti Dual Line CTFS 28
- Tahiti Dual Line RTFS 24
- Tahiti Dual Line RTFS 28
How to choose the right gasket
When selecting a gasket, it is important to pay attention to the following parameters:
- Diameter: Ensure that the inner and outer diameters of the gasket match the size of your boiler's fan.
- Thickness: The thickness of the gasket should match the original part to ensure a reliable seal.
- Material: Make sure the gasket is made from high-quality material that is resistant to high temperatures and gas exposure.
Possible causes of failure and prevention methods
Gasket failures can occur for the following reasons:
- Wear: Gradual aging of the material leads to leaks. Regularly checking the condition of the gasket can help avoid problems.
- Improper installation: Incorrect installation can damage the gasket. Always follow the manufacturer's instructions when replacing.
To prevent wear, it is recommended to periodically check the condition of the gasket and replace it at the first signs of damage.
Difficulty of replacement
Replacing the fan gasket is a relatively simple procedure that can be done independently. Follow these steps:
- Disconnect the boiler from the power supply and turn off the gas supply.
- Remove the protective cover and fan.
- Take out the old gasket and clean the surface of any material residue.
- Install the new gasket, ensuring it is properly positioned.
- Reassemble the fan and protective cover.
- Turn on the boiler and check for leaks.
The overall difficulty of replacement is rated as low, but if you are unsure of your abilities, it is recommended to consult a professional.