Quantity
|
Out of stock
|
||
|
|
|||
|
|
|||
Gas valve for Gorenje stove (oven) (304985)
The gas valve for Gorenje stove and oven (304985) is designed to control the gas supply in gas stoves and ovens. This reliable component ensures safe and efficient use of gas appliances. Perfect for repairs and replacements in various kitchen appliance models, it guarantees durability and stable operation of your equipment.
Technical specifications and compatibility
| Model | Code |
|---|---|
| Asko CG9632W | 438860, K24E1-134VE |
| Atag FG6011EA1E/A02 | 242035, K24H1-134VE |
| Bauknecht BK67220IX | 290820, K24E1-244VM |
| Baumatic BT2365TCSS | 161918, K44D1-234VD |
| Bellers BL5059W | 170708, K53E1-V3VD |
| Eskimo ESK4320GW | 342203, K23B1-134VM |
| Gorenje EK446W | 193444, K53E1-13VD |
| Junex GL552WB | 294557, P21B1-26VT |
| Korting KGI62123HX | 335588, P21A1-26VT |
| Mora 2606.0A32 | 293087, K51E1-V4VD |
| Pelgrim PF8201RVSA | 511941, K34D1-134VM |
| Whirlpool ACH104NB WHI | 335416, K51E2-V4VD |
How to choose the right product
When selecting a gas valve, it is important to pay attention to the following points:
- Compatibility: Ensure that the valve model is suitable for your device. Check compatibility with the listed models and codes.
- Connection type: Note the type and size of connections to avoid installation issues.
- Material quality: Choose parts made from reliable and corrosion-resistant materials for durability.
Possible causes of malfunction and prevention methods
The main causes of gas valve malfunction may include:
- Wear of sealing rings, leading to gas leaks.
- Corrosion or damage to the valve body.
- Clogging of the mechanism from deposits or dirt.
To prevent wear and damage to the valve, it is recommended to regularly check and clean it, as well as replace sealing rings at the first signs of wear.
Difficulty of part replacement
Replacing the gas valve can vary in difficulty depending on the device model. Generally, the process includes the following steps:
- Turn off the gas and disconnect the stove from the power supply.
- Remove the outer panels to access the valve.
- Disconnect the old valve by carefully unscrewing the fasteners.
- Install the new valve following the installation instructions.
- Check all connections for leaks before reconnecting the device to the gas supply.
Difficulty rating for replacement: moderate. It is recommended to carry out the replacement with the help of a qualified specialist if you do not have experience working with gas equipment.